Low Flow,micro,mini flow meters for gas,liquid measurement
SILVER AUTOMATION INSTRUMENTS LTD.

By Media
Flow Meter

Low-Flow Flow meter


When talking about small lines and low flow rates gas and liquid flow measurement, we have some reliable recommendations, such as mini thermal mass flow meters, low flow liquid turbine flow meter, metal tube Rotameter. See below general introductions for the rugged low flow meters also at low price cost.

Low flow mag meters -Strong corrosive liquid flow measurement

Low flow mag meters can handle liquid flow as low as to 330 ml/min (min flow rate 0.09GPM), the mini mag flow sensor size we can provide is 1/8”,1/4”,3/8”,1/2”,3/4”. Micro flow magnetic flow meters are used widely in chemical or fertilizer injection industries.it can measure strong aggressive and corrosive liquid, such as HCL, H₂SO₄,  caustic soda,  Phosphoric acid, hydrofluoric acid (HF acid),nitric acid.,etc
Flow range and Size

Size mm   size (inch)    Flow range( m3/h)         Flow range(GPM)

4mm         1/8”         0.02-0.4m³/h              0.09- 1.76 GPM

6mm         1/4”         0.05-1 m³/h               0.22-4.4 GPM

10mm       3/8”         0.14-2.7 m³/h             0.62-11.89 GPM

15mm       1/2”         0.3-6 m³/h                1.32-26.42 GPM


Micro type Low flow Thermal Mass Flow meter-Gas &air flow measurement

It employs the thermal dispersion principle whereby the rate of heat absorbed by a gas or air flowing in a closed pipe or duct is directly proportional to its mass flow passing.

Thermal flow meters are frequently used for the regulation of low gas flows or air flow, It is a kind of gas flow controller.

Features:

Low Gas flow range:

DN(mm)

Min(mL/min)

Max(mL/min)

Min(L/h)

Max(L/h)

3

0.000

21000

0.000

1272

4

0.000

37000

0.000

2261

6

0.000

84000

0.000

5100

8

0.000

150000

0.000

9050

10

0.000

235000

0.000

14137

Digital display of gas volume flow and mass flow measurement, flow velocity
4-20mA, pulse and RS485 communication
Gas flow measurement without external temperature and pressure compensation
High accuracy: ± 1 ~2.5 %

Micro oval gear flow meter  -High viscosity and low flow rate measurement

LC-M Series Micro oval Gear flow meter can detect ultra mini liquid flow as low as 0.5 ml/min, but can still keep accuracy as high as 0.5%F.S, It is a kind of positive displacement flow meter for precise flow measurement of mini or low flow liquid, the liquid include chemical, sealant, toluene, glue, detergents, grease, electrolyte, ethylene, additive, syrup, acryiat-composite.,etc . It is widely used in hydraulic system, lubricating industry and painting industries for fluids low-flow rate measurement.

Features

✔ High accuracy: +/-0.5FS
✔  Fluids temperature: -30~80℃,optional high temperature
✔ Operation pressure: 5Mpa, optional high pressure
✔ Output: pulse output (hull or Reed Switch)
✔ Max frequency: 0.03 ml/p
✔ Power supply: 4-26V DC
✔ Process connection: stainless steel 316L
✔  Material: stainless steel 316L or anodized aluminum

Metal Tube Rotameter for small flow measurement-Gas ,liquid measurement

Metal tube rot meter is a kind of variable area (VA) flow meter; Rotarmeter is with a tapered tube, a float and scaled indicator, measured medium flow raises a float in the tapered metal tube, adding the area for passage of the fluid

Features:
Low flow range

Water (L/h)

Air (m3/h)

Vertical Mounting

Max Pressure los

Diameter

Float No.

Flow range

@0.1013MPa 20°C

Water

(Kpa)

Air

(Kpa)

Measuring tube 15 mm

H15.1

H15.2

H15.3

H15.4

H15.5

H15.6

H15.7

H15.8

H15.9

1.6~16

2.5~25

4.0~40

6.3~63

10~100

16~160

25~250

40~400

63~630

0.05~0.5

0.07~0.7

0.11~1.1

0.18~1.8

0.28~2.8

0.48~4.8

0.7~7

1.0~10

1.6~16

2.0

2.3

2.5

2.5

2.5

2.6

2.7

2.9

3.4

7.0

7.2

7.3

7.5

7.8

8.0

10.0

10.8

14


Can work for small flow measurement of gas and liquid
Mechanical type pointer to show instant flow, do not need external main power
Metal tube variable area flow meter option with transmitters to have analog outputs
Vertical mounting and horizontal mounting options
With alarm contact outputs for flow controlling processes purpose
Option with different material, even supply VA rotameter with PTFE lined material for corrosive liquids and gases measurement

Low Flow Liquid Turbine Flow meter-clean liquid measurement

It is only dedicated to measure clean and not corrosive liquids, cannot measure gas.Perfect choice low flow meter for oil.

Miniature turbine flow meter is suitable to measure clean and non-corrosive liquids

Flow range

Flow range

Flow sensor size

Flow (L/min)

K factor (cm3/imp)

1.15mm

0.035~1.6

0.50

1.3mm

0.01~1.86

0.60

1.5mm

0.045~2.08

0.67

2.0mm

0.085~2.32

1.02

2.5mm

0.12~2.4

1.44

3.7mm

0.15~3

2.28

Coriolis flow meter for low flow fluids measurement-liquid ,gas and steam measurement

Coriolis meter can measure liquid, gas and steam; it can have mass flow, temperature and density measurement by one flow sensor. It can have small sizes low to DN1.5-DN8 size.

Features

Flow range:

DN

Flow Range

Operation Pressure

Process Connection

1.5

0~4 kg/h

0~32 Mpa

Weld Joints Φ6×1.5

3

0~40 kg/h

0~32 Mpa

Weld Joints Φ6×1.5

6

0~100 kg/h

0~25 Mpa

Weld Joints Φ10×2

8

0~200kg/h

0~20 Mpa

Weld Joints Φ10×1

High Flow Accuracy: ±0.2%~±0.1%

Medium Temperature range:-50°C~ +350°C,

Analog outputs, frequency outputs, RS485 Modbus RTU and Hart Protocol

  • LC-M Series Micro Oval Gear Flow MeterLC-M Series Micro Oval Gear Flow Meter2019/07/05LC-M Series Micro oval Gear flow meter candetect ultra mini liquid flow as low as 0.5 ml/min, but can still keep accuracyas high as 0.5%F.S, It is a kind of positive displacement flow meter forprecise...view
  • Micro low flow Coriolis flow meterMicro low flow Coriolis flow meter2019/06/05Micro Coriolis flow meter provides the accurate mass flow measurement of low flow fluids, the flow rate can be as low as 0~40 kg/hr, It is operated base on the Coriolis force principle, and mini mass ...view
  • Low flow magnetic flow meterLow flow magnetic flow meter2019/07/11Low flow mag meters can handle liquid flowas low as to 0.33 LPM (0.09GPM), the mini mag flow sensor size we can provideis 1/8”,1/4”,3/8”,1/2”,3/4”. Micro flow magnetic flow meters are used widely...view
  • Micro-Flowrate Thermal Mass Flow MeterMicro-Flowrate Thermal Mass Flow Meter2018/03/02Micro-flowrate Thermal mass flow meter for DN3-DN10,China gas flow meter for LPG,biogas ,natural gas.etcview
  • Low Flow Liquid Turbine Flow meterLow Flow Liquid Turbine Flow meter2018/11/22Mini-flowmeter to measure Low flow rate from 0.035 L/min to 3 L/min for clean and non-corrosive liquids flow measurement.view
  • Low flow rotameterLow flow rotameter2019/06/06Metal tube rotameter can work on the water low flow min to 1.6 Liter/hour, it can be used to detect fluids micro flow rate. Metal tube variable area flowmeter is one of the oldest flow measurement tec...view